G5PZ-1A-X DC12 BY OMZ 数据手册
G5PZ-X
PCB Power Relay
Compact Power Relay that Enables
Bidirectional Opening/Closing of
200 VDC, 20 A
• 400 VDC, 20 A bidirectional opening/closing is also possible through a contact
series connection between two product units
• The 15.2 mm (W) slim size enables opening/closing of 200 VDC, 20 A regardless
of the polarity
• High sensitivity of 530 mW coil consumption (further energy-saving effect is
realized in an operating environment with a holding voltage of 50%)
• Min. 5.5 mm of insulation distance between the coil and contacts, and high
insulation of 10 kV impulse withstand voltage
• A rating of two-contact series connection is acquired through UL/TÜV/CQC
RoHS Compliant
■Model Number Legend
G 5 P Z - 1 A @- X
———
•
•
•
•
1 2 3
1. Number of Poles
1 : 1-pole
G
5
P
Z
I
X
■Application Examples
2. Contact Form
A : SPST-NO (1a)
3. Rating
None : Flux protection
Battery system
OA equipment
FA equipment
UPS
■Ordering Information
Contact form
Enclosure rating
SPST-NO (1a)
Flux protection
Model
Rated coil voltage
Minimum packing unit
G5PZ-1A-X
12 VDC
24 VDC
80 pcs. / Tray
Note 1. When ordering, add the rated coil voltage to the model number.
Example: G5PZ-1A-X DC12
Rated coil voltage
However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@VDC.
■Ratings
●Coil
Item
Rated current (mA)
Coil resistance (Ω)
Must-operate voltage (V)
Rated voltage
Must-release voltage (V)
Max. voltage (V)
Power consumption (mW)
140%
(at 23°C)
Approx. 530
% of rated voltage
12 VDC
44.1
272
24 VDC
22.1
1087
75% max.
5% min.
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
Note 2. The operating characteristics are measured at a coil temperature of 23°C.
Note 3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
●Contacts
Item
Connection
method
One-contact connection
(Resistive load)
Contact type
Single
Contact material
Rated load
Ag-alloy (Cd free)
20 A at 200 VDC
Rated carry current
Max. switching voltage
Max. switching current
Two-contact series connection
(Resistive load)
20 A at 400 VDC
20 A
200 VDC
400 VDC
20 A
1
G5PZ-X
PCB Power Relay
■Characteristics
Connection
method
Item
Contact resistance *1
100 mΩ max.
Operate time
15 ms max.
Release time
5 ms max.
Insulation resistance *2
Dielectric
strength
Impulse
withstand
voltage
Vibration
resistance
Shock
resistance
Durability
Two-contact series
connection
1,000 MΩ min.
Between
coil and contacts
4,000 VAC 50/60 Hz 1 min
Between
contacts of the
same polarity
1,000 VAC 50/60 Hz 1 min
Between
coil and contacts
10 kV (1.2 x 50 μs)
Destruction
10 to 55 to 10 Hz, 0.75 mm single amplitude
(1.5 mm double amplitude)
Malfunction
10 to 55 to 10 Hz, 0.75 mm single amplitude
(1.5 mm double amplitude)
Destruction
1,000 m/s2
Malfunction
200 m/s2
Mechanical
G
5
P
Z
I
X
One-contact
connection
Electrical
(resistive load)
2,000,000 operations min.
1,000 operations
at 200 VDC, 20 A
1,000 operations
at 400 VDC, 20 A
100,000 operations
at 200 VDC, 0.25 A
100,000 operations
at 400 VDC, 0.25 A
Ambient operating temperature
-40 to 85°C
(with no icing or condensation)
Ambient operating humidity
5 to 85%
Weight
Approx. 15 g
Approx. 15 g x 2 pcs.
Note1. Values in the table above are the default (ambient temperature 23°C)
values.
Note 2.Refer to the Circuit Diagrams for the connection method of a two-contact
series connection.
Note 3.Refer to Correct Use when opening/closing a micro load.
*1. Measurement conditions: 5 VDC, 1 A, voltage drop method
*2. Measurement conditions: Measured at the same points as the dielectric
strength using a 500 VDC ohmmeter.
■Dimensions
CAD Data
Please visit our website, which is noted on the last page.
G5PZ-1A-X
Terminal Arrangement/
Internal Connections
(Bottom View)
PCB Mounting Holes
(Bottom View)
Tolerance: ±0.1 mm
15.2 max.
(15.0)*
26.4 max.
(26.2)*
(Unit: mm)
16.5
29.5 max.
(29.3)*
Two, 1 dia.
0.5
4 0.4x0.4
0.4
0.4
1
2
4
3
20
Two, 1.3 dia.
(No coil polarity)
1
*Average value
2
1
7.5
CAD Data
G5PZ-X
PCB Power Relay
■Approved Standards
The approval rating values for overseas standards are different from the performance values determined individually. Confirm the values
before use.
●UL Recognized:
(File No. E41515)
Model
Contact form
Coil ratings
G5PZ-1A-X
SPST-NO(1a)
12 to 24 VDC
*1.
Contact ratings
(One-contact connection)
20 A, 200 VDC (Resistive) 85°C
Contact ratings
(Two-contact series connection)
Number of
test operations
20 A, 400 VDC (Resistive) 85°C *1
1,000
Two-contact series connections only comply with UL standards
●EN/IEC, TÜV Certified:
(Certificate No. R50408241)
Model
Contact form
Coil ratings
G5PZ-1A-X
SPST-NO(1a)
12 to 24 VDC
●CQC Certified:
Contact ratings
(One-contact connection)
20 A, 200 VDC (Resistive) 85°C
Contact ratings
(Two-contact series connection)
Number of test
operations
20 A, 400 VDC (Resistive) 85°C
1,000
(Certificate No. CQC21002317552)
Model
Contact form
Coil ratings
G5PZ-1A-X
SPST-NO(1a)
12 to 24 VDC
Creepage distance
Contact ratings
(One-contact connection)
20 A, 200 VDC (Resistive) 85°C
Contact ratings
(Two-contact series connection)
Number of test
operations
20 A, 400 VDC (Resistive) 85°C
1,000
8.0 mm min.
Clearance distance
5.5 mm min.
Insulation material group
III a
Type of insulation coil-contact circuit
open contact circuit
Basic
G
5
P
Z
I
X
Type of disconnection open contact circuit
Micro disconnection
Rated insulation voltage
200 VDC (One-contact connection)
400 VDC (Two-contact series connection)
Pollution degree
3
Rated voltage system
250 V
Over voltage category
III
Category of protection according to IEC 61810-1
RT II
Tracking resistance according to IEC 60112
PTI 250 V min. (housing parts)
Flammability class according to UL94
V-0
■Circuit Diagrams
●One-Contact Connection
1
2
4
3
●Two-Contact Series Connection
1
2
4
3
1
2
4
3
Load
Load
Note. The diode and zener diode are for the absorption of coil surge. (The coil does not have a polarity.)
The opening/closing part does not have a polarity.
3
G5PZ-X
PCB Power Relay
■Precautions
●Please refer to “PCB Relays Common Precautions” for correct use.
Warning
As this relay is a high-voltage and high-current type,
there is a risk of abnormal heat generation, smoke
generation or fire if you use the relay with a contact
voltage, current, or for a number of times beyond the
specified range. Use only within the specified ranges.
• The coil has no polarity. Connect the diodes in the reverse
polarity of the voltage applied to the coil.
• The recommended zener voltage of the zener diode is one to
three times of the coil rated voltage.
Diode
Relay Coil
Zenor Diode
Correct Use
●Handling
This product has a flux-resistant protection structure. Therefore,
do not perform immersible cleaning.
●Coil Voltage Reduction (Holding Voltage) after Relay
Operation
• If the coil voltage is reduced to the holding voltage after relay
operation, first apply the rated voltage to the coil for at least
100 ms, as shown below.
• A voltage of at least 50% of the rated voltage is required for
the coil holding voltage. Do not allow voltage fluctuations to
cause the coil holding voltage to fall below this level.
G
5
P
Z
I
X
100%
(Rated voltage)
50%
(Holding voltage)
Rated voltage
100%
Holding voltage
50%
*
Power
consumption
Coil resistance*
272 Ω (12 VDC)
1087 Ω (24 VDC)
• These relays must be used for high DC voltages. The final
failure mode is failure to break the circuit. In a worst-case
scenario, burning may extend to surrounding components.
Do not use these relays outside of the specified ratings and
service life, or for any application other than high DC voltages.
Implement safety circuits and other safety measures to
minimize the risk in case of the unlikely event of a failure.
• The electrical durability of these relays is specified as the
number of load switching operations under a resistive load and
OMRON-specified standard testing conditions.
The coil drive circuit, ambient environment, switching
frequency, or load conditions (e.g., inductive load or capacitor
load) may reduce the service life and possibly lead to failure to
break. Always confirm the service life in the actual equipment.
●Micro Loads
100ms min.
Applied
coil voltage
●Relay Service Life
Approx. 530 mW
These power relays are suitable for switching and breaking highcapacity DC. At high-voltage and low-current, breaking
characteristics may become unstable. For switching applications
at a range between 0.5 A and 2 A, please consult us.
Approx. 133 mW
The coil resistance was measured at a coil temperature of 23°C with
tolerances of ± 10%.
●Connection of Diodes to the Operating Coil
• Connect a diode and zener diode to the relay coil (refer to the
following figure).
• The diodes are for coil surge absorption. Switching
performance may be affected if only a diode is used, so use in
combination with a zener diode.
●Installation Intervals
When using a two-contact series connection, ensure an interval
of at least 10 mm between the product units.
●Electrical Appliances and Materials Safety Act
The G5PZ-X series does not comply with the Electrical
Appliances and Materials Safety Act. Please select our relays
carefully in accordance with the application you wish to use the
product for.
Please check each region's Terms & Conditions by region website.
OMRON Corporation
Electronic and Mechanical Components Company
Regional Contact
Americas
https://www.components.omron.com/
Asia-Pacific
https://ecb.omron.com.sg/
Korea
https://www.omron-ecb.co.kr/
Europe
http://components.omron.eu/
China
https://www.ecb.omron.com.cn/
Japan
https://www.omron.co.jp/ecb/
© OMRON Corporation 2021 All Rights Reserved.
In the interest of product improvement, specifications are subject to change without notice.
4
Cat. No. K339-E1-01
0921(0921)